Plant map

The plant map is a drawing of the shop you make from rectangles, circles, lines and labels on a grid, with the real tanks, areas, tank groups, equipment, racks and polishing stations placed on it. On top of the drawing, heat maps colour what the shop records: tank temperature and pH against their limits, SPC signals, amp-hours since the last addition, work in process, who is clocked in where, and, over a date range, rejects, maintenance due, tank utilisation, chromium air sampling and invoiced or spent dollars by area.

Drawing the map

Administrators draw the map under Setup > Plant map; everyone else views it. The paper is a grid of map units (2400 by 1600 by default, with a grid of 20; Map size changes both) and the tools along the left are Select, Pan, Rectangle, Ellipse, Line, Arrow, Wall and Text, with a Safety menu that drops a marker. A rectangle is given a meaning in the Properties panel: a plain rectangle, an office, chemical storage, wastewater treatment, a scrubber, a dock, a door, an aisle, a kiosk or a rack area. Every shape can be dragged, resized with its handles, rotated with the round handle above it and nudged with the arrow keys; shapes snap to the grid unless Alt is held, several are selected with a marquee or Shift-click, and the toolbar aligns and distributes them, duplicates, groups and ungroups, locks, sends them forward or back, and undoes and redoes every step. Copy and paste work within the editor. Each shape has a fill, a stroke and a text colour from the app's palette or any colour you pick, a stroke width, a dash, an opacity, a font size, a corner radius, and a note that the viewer shows when the shape is clicked; an arrow chooses its heads, a wall or line can be closed, a door its swing, and a kiosk shape carries a link to the page the kiosk on the floor shows.

The real records. The map is not just a picture: drag a tank, area, tank group, equipment, rack or polishing station from the Import panel onto the map, or place all the areas and then all the tanks in their areas with two clicks. The panel lists what is not placed yet, section by section, with a search box; Place all unplaced tanks of area puts one area's tanks inside its zone, and Place all racks into the selected rectangle fills a rack room. A placed tank shows its code and name and is coloured by the heat maps; an area, a tank group and a rack area are drawn as zones you grab by their edge or their name, so the tanks inside them stay selectable. An office, chemical storage, wastewater treatment, scrubber or dock can be linked to an equipment record where one exists, and the maintenance heat map colours it. A record stands on one map once: a tank placed on the Annex map is not offered on the Plant map, and the panel says where it is. Rack storage is drawn as a rack area: a rack area on the map counts the racks whose location is its name, and the viewer lists them. Safety fixtures are placed from the Safety menu: eyewash stations, showers, extinguishers, spill kits, exits and first-aid kits are markers of their own.

Layers and maps. Shapes sit on layers (Walls & doors, Areas & lines, Tanks & equipment and Notes to begin with, plus any you add), each with an eye to hide it and a lock to keep its shapes still; the layer you draw on is picked in the Layers panel. A shop can have several maps, shown as tabs: one per building or floor; most shops have one. New map, Rename, Move up and down and Delete are on the Plant map list; the last map cannot be deleted, and a map holds at most 2,000 shapes.

Saving. Save (Ctrl+S) writes the whole map at once, and the page asks before you leave with unsaved changes. The editor is a live page: it shows who else has it open, and when two administrators edit the same map, the second save is refused with the name of the first and a choice: reload, or save over. A bar also says "Ana Lopez saved this map" with Reload the moment someone else saves it. The editor needs a screen at least 900 px wide; narrower than that it offers the viewer instead.

In the editorKeys
Select toolVclick a shape; Shift+click toggles; click empty paper clears; a zone is grabbed by its edge or its name
Clear selection / cancelEsc
Select allCtrl+A
Next / previous shapeTab Shift+TabEnter selects the shape under focus
Movedragsnaps unless Alt is held
Nudge one grid / five grids / one unit←↑→↓ Shift+←↑→↓ Alt+←↑→↓
Resizedrag a handleShift keeps the ratio; snaps unless Alt
Rotatedrag the round handleShift snaps to 15°
Snap to gridG
Show gridCtrl+'
Align / distributebuttonsthe Align menu; no chord
DuplicateCtrl+D
Copy / Cut / PasteCtrl+C Ctrl+X Ctrl+Vpasted at the pointer, each repeat one grid further; a cut shape keeps its record link, a copy of a tank or other linked shape becomes a plain rectangle with its words (a record stands once on the map)
DeleteDelete Backspace
Group / UngroupCtrl+G Ctrl+Shift+G
Bring forward / send backwardCtrl+↑ Ctrl+↓
Bring to front / send to backCtrl+Shift+↑ Ctrl+Shift+↓
Lock / unlockCtrl+L
Draw rectangle / ellipseR Ethen drag, or click for the default size
Draw line / arrow / wallL A Wclick points; Shift constrains to 0/45/90°; double-click or Enter ends; Shift+Enter closes; Esc cancels
TextT
Pan toolH Spacehold Space to pan while another tool is on
Zoom in / out / fit / 100%+ - 0 Ctrl+0the wheel zooms about the pointer
Undo / RedoCtrl+Z Ctrl+Shift+Z Ctrl+Y
SaveCtrl+S
This list?⌘ counts as Ctrl on a Mac

Viewing the map

Map, under Production, shows the drawing to every staff role, with tabs when the shop has more than one map. The bar above it has two pickers, Colour and Badge, each listing the live heat maps and then the period ones: two heat maps at once: one as colour, one as a number badge; with both on, the colour's number stays on the shape. Pick Tank temperature for colour and Work in process for the badge and each tank shows its temperature in its colour with the pieces at it beside. The legend is always shown; every colour also carries a number or a symbol: ▲ above the limit, ▼ below it, ! hot, ~ older than its test interval; a tank the shop does not test for a heat map stays plain. The legend names what each colour means, the range of each step, what counts as hot (hot shapes are hatched), and the small print of the heat map: how many tanks are not tested for it, who is clocked in but not on a step, the period. Click a shape and a card says what it is, what each heat map says about it and why, the people on it with how long they have been there, the jobs with their quantities and due dates, the racks in a rack area, the drawer's note, and a link: a tank opens its tank page, an area its jobs on the schedule board, a person their timecard, equipment its page.

Now, or over a period, or replayed. Live heat maps update as the shop works, through the same live connection the other pages use; a wall screen refreshes itself every five minutes as well, and says so in large type when it has stopped updating. The page says when its numbers are from ("as of 10:42"). Period heat maps take a date range, the last 30 days unless you change it, at most a year. A heat map marked Playback in the table below can replay one day with a slider, Play and a speed, in frames of 5 to 60 minutes: pick the day, press Play and watch the pieces move and the people come and go; the frame time shows in the bar, the slider scrubs, and Live goes back to now. The badge keeps its own playback when it has one, else its live value with "(now)" in the legend.

Kiosk. Kiosk opens the map full screen for a wall TV, with larger type, strong colours, no sidebar, and a clock; it zooms through the areas in turn, or stays on whatever is hot. The address carries the heat maps, the period, the day and the view (cycle, hot or the whole map), and can name several pairs of heat maps to rotate between every half minute, so one bookmark on the TV's browser brings the screen back after a restart. A playback day on the kiosk plays by itself and loops. A clicked shape shows its card for 20 seconds without links; Fullscreen is a button, since browsers only go full screen on a click; Esc leaves full screen, then the kiosk.

Layers, strong colours, print and export. The Layers menu hides any layer of the drawing, and Strong colours switches to the saturated palette the kiosk always uses, for a bright room or a projector; dark mode has its own shades of the same colours. Print puts the whole map on one landscape page with the legend below it. Export PNG saves the map as a picture named after the map and the date, with the legend drawn in, at twice the map's size up to 8,192 pixels on the longest side, ready for a slide, an email or a notice board. The address keeps the heat maps, the period, the day, the layers and the zoom, so a bookmark or a link pasted in a message opens the same picture.

Phone. On a phone the map pans and zooms with one finger and a pinch; it is view-only there. A double tap fits the whole map, Colour and Badge stay on top with the rest of the bar behind ⋯, Legend opens the legend as a sheet, and a tapped shape's card slides up from the bottom; the page itself never scrolls.

The heat maps

Fourteen heat maps, each reading records the other pages keep. The colour of a shape is chosen one of three ways. A heat map against limits (temperature, pH) is green within them, amber within 5% of the span of a limit, red outside; a tank with no limits set keeps its number and stays plain. A status heat map (SPC signals, amp-hours, maintenance, Cr(VI)) gives each colour a fixed meaning, written in the legend. A count or an amount shades from light to dark in five steps: for work in process, rejects and the dollar heat maps the darkest step starts at the 90th percentile of the places that have anything, so one very busy place does not wash out the rest, and work in process scales areas and tanks apart; people and tank utilisation use fixed bands (1, 2–3, 4–6, 7 or more; quarters of the capacity). Every colour carries its number, so nobody has to judge a shade, and a shape that is hot is hatched as well.

Heat mapWhenWhat it showsWhere the numbers come fromHot
Tank temperatureLive, playbackThe latest bath temperature of each tank against its limits, in the tank's unitThe lab's Temperature line, or the last run logged on the tank, whichever is newer; limits from the Temperature line's control plan, else the tank's operating windowout of its limits
Tank pHLive, playbackThe latest pH test of each tank against its pH line's limitsThe tank's pH line (the operating pH on the tank form), from tank testsout of its limits
SPC signals openLiveOpen SPC signals on each charted tank: none green, one amber, two or more redSPC signals on the tank's parameters; a tank with no chart is not colouredan open SPC signal
Amp-hours since additionLiveAmp-hours run through each rectified tank since its last brightener or additive, and what that asks to add; a requested add shows amberThe tank's amp-hour counter, its additive and rate per 1,000 A·h, and open add requestsa whole unit of additive is due
Work in processLive, playbackPieces waiting and in progress at each area and tank, with the jobs they belong toThe steps of open jobs, from step tracking, and the loads on themholds pieces of a late job
People clocked inLive, playbackWho is clocked in, placed on the area and tank of the step they are workingTime clock punches and the labor entries opened by Start on the floornever (the busiest place is not a fault)
RejectsPeriod, playbackRejected pieces in the period by the step they were found at: its area, tank or polishing operation. Rejects found at a polishing inspection count on the step's first operation.Rejects recorded on the job, at completion or by QCnever (the busiest place is not a fault)
Maintenance duePeriodEquipment and tanks due or overdue for maintenance, calibration or a dump, and open work orders, as of the end of the period: due within 14 days or with an open work order amber; retired equipment plainEach asset's next PM and calibration dates, its PM templates by calendar or meter, a tank's next dump and the open work ordersoverdue, or out of service
Tank utilisationPeriod, playbackLogged dwell minutes per tank as a share of its area's working hours over the weekdays of the period; over capacity redRuns and loads completed in the period; the area's capacity hours per day (8 when none is set)90% of capacity or more
Cr(VI) air samplingPeriodThe worst hexavalent chromium air sample per area in the period, banded against the action level and the PELThe Cr(VI) exposure records, matched to an area by the code or name typed on the sample; areas that match nothing are listed in the legendabove the PEL
Invoiced by areaPeriodInvoiced amounts in the period, each job's split evenly across the areas its steps ran inInvoice lines with a job on them, by invoice datenever (the busiest place is not a fault)
Labor cost by areaPeriodLabor cost and hours clocked on each area's steps in the periodLabor entries started in the period, on the area of their stepnever (the busiest place is not a fault)
Chemistry cost by tankPeriodThe cost of chemical additions to each tank in the periodTank additions at their recorded unit costnever (the busiest place is not a fault)
Bake tests runningLiveThe bake adhesion tests in each oven (equipment of the type oven): the minutes left, the time up and waiting for the inspector, or no result within the grace timeThe bake tests started on the QA tests pages, the floor card or the job page, and the Bake tests settings (the grace time)the time is up and no result came within the grace time

Tank temperature and pH come from the latest lab result, or, for temperature, the latest run logged on the tank, whichever is newer; a reading older than the tank's test interval (at least a day) shows as stale and keeps its last colour. Work in process counts the pieces waiting at and being worked at each area and tank, from step tracking; jobs received before step tracking are not counted. An area or tank is hot when it holds pieces of a late job. Playback shows pieces being worked, not pieces waiting. Tank utilisation counts the weekdays in the period as capacity. Invoiced by area splits each job's invoiced amount evenly across the areas its steps ran in. Dollar heat maps are for the roles that see prices and costs; other roles do not see them in the list. Cr(VI) air sampling is for administrators and managers.

Playback, frame by frame. A frame holds the state at its start minute on the shop's clock. Temperature and pH begin the day at the last reading before it and step at each test or run; work in process adds a portion's pieces when it starts and takes them off when it completes; people come from the punches and labor entries that overlap the frame; rejects add up through the day; tank utilisation shows a tank running for the dwell of each run that ended that day and counts the runs so far.

What the map is not

The map is schematic: no real dimensions, no scale, no background drawing or photo, no CAD import, no 3D. Shapes mean what you say they mean. Heat maps show only what the app records: a tank with no temperature in its tests or runs has no colour, and a shop that does not clock labor to steps has no people on the map. Playback replays the records of a day, not a video of the floor.

Nothing on the map changes a record: deleting a tank's shape removes it from the drawing only. A tank or piece of equipment deleted elsewhere keeps its shape, marked as a record that no longer exists, until an administrator unlinks or deletes it; a retired one keeps its place and shows its status.

Who sees it

  • Administrators draw the map (Setup > Plant map) and see every heat map.
  • Every staff role views it under Production > Map, with the heat maps its role may read: a heat map that reads the lab needs Tanks, people needs Time or Production, rejects needs Quality or Production, maintenance needs Maintenance, and so on; roles that do not see prices and costs do not see the dollar heat maps in the list, and Cr(VI) air sampling is for administrators and managers.
  • Custom roles see the map when their role includes Production.
  • The customer portal never shows it.